M.U.D. crews are performing water main work in Harrison St., from 78th to 108th Sts. Customers may experience low water pressure in the Ralston and La Vista areas during this work. We apologize for any inconvenience this may cause.
Gas leaks, odor of gas, damaged lines, carbon monoxide symptoms and water main breaks are all considered emergencies.
If you smell gas, do not attempt to locate the leak. Instead, leave the house or building right away. Do not use any electrical switches, appliances, lights, telephones, or mobile devices, as an electrical charge could create a spark. When you are in a safe place, call M.U.D.'s emergency hotline at 402.554.7777 or 9-1-1.
If someone is showing symptoms of carbon monoxide poisoning, call 9-1-1 immediately. Symptoms are like the flu.
If you have a water-related emergency, call 402.554.7777. Our personnel are ready to assist you 24/7. When in doubt, call us immediately.
Learn MoreLas fugas de gas, el olor a gas, las tuberías de gas dañadas, los síntomas de monóxido de carbono y roturas en las tuberías principales de agua son consideradas emergencias.
Si huele a gas, NO trate de localizar la fuga/escape. Al contrario, abandone la casa o el edificio inmediatamente. No utilice los interruptores eléctricos, electrodomésticos, luces, teléfonos o equipos móviles, ya que una carga eléctrica podría provocar una chispa. Una vez que se encuentre en un lugar seguro, entonces llame a la línea directa de emergencia de M.U.D. al 402.554.7777 o al 9-1-1.
Si alguien tiene síntomas de envenenamiento causados por el monóxido de carbono, llame al 9-1-1 inmediatamente. Los síntomas son como los de la gripe/catarro.
Si tiene una emergencia relacionada con el agua, llame al 402.554.7777. Nuestro personal está listo para ayudarle, 24/7. Cuando dude o crea que hay una emergencia, llámenos de inmediato.
Aprende MásLetter to District Holders [04-07-23]
Standardize Ductile Iron Pipe to Class 52
100-14 [Rev ] Specifications for Dry-Barrel Fire Hydrants
107-00 Specifications for Coated and Cement-Lined Steel Pipe and Fittings
109-09 [Rev ] Precast Concrete Manholes
110 [Rev ] Ductile Iron Pipe for Water Distribution Service
111 [Rev ] Ductile Iron Fittings
119 [Rev ] Specifications for Materials
120 [Rev ] Specifications for Construction
122-14 Specification for Resilient Seated Gate Valves for Water Supply Service
123 [Rev ] High Density Polyethylene (HDPE) Pipe and Fittings for Water Distribution Service
126 [Rev ] Polyvinyl Chloride (PVC) Pipe for Water Distribution Service
E.225.2 [Rev ] Welding Procedure — Shielded Metal Arc Welding
E.225.3 [Rev ] Welding Procedure — Gas Metal Arc Welding
E.225.4 [Rev ] Welding Procedure — Oxy-Acetylene Welding
E.227.0 [Rev ] Qualification of Welders
E.229.0 [Rev ] Visual Inspection of Test Welds
0.2.1 [Rev ] Installation of Erosion and Sediment Control
0.3.0 [Rev ] Shoring Installation Requirements
1.1.6 [Rev ] Abandonment of Vaults and Valve Boxes
1.3.0 [05-19-22] Bypass Piping
1.4.0 [Rev ] Pressure-Testing Water Mains
1.4.3 [Rev ] Chlorination of Water Mains
1.4.4 [Rev ] Disinfecting and Flushing Main Repairs and Connections
1.6.1 [Rev ] Air Taps on Ductile Iron, Cast Iron, PVC, and HDPE Water Mains 16-inch and Smaller
1.6.2 [Rev ] Sample Taps on Ductile Iron, Cast Iron and PVC Water Mains, 16-inch and Smaller
1.8.1 [Rev ] Precast Vault Installation — Water
1.8.3 [Rev ] Reinforced Vault Footings & Concrete Slab Design
1.8.4 [Rev ] CC Box Installation — Water
1.8.11 [Rev ] Typical Backing Blocks for Water Mains
1.8.12 [Rev ] Immediate Support Backing Blocks (ISBB)
1.8.13 [Rev ] Screw Jacks for Support Backing with Extra Heavy (Sch 80) Black Pipe
1.9.1 [Rev ] Swivel x Solid Adapter for 6-inch to 12-inch Water Main
1.10.1 [Rev ] Excavations for Tapping Sleeves and Tees
1.11.1 [Rev ] Backfill Compaction for 16-inch and Smaller Water Mains
1.11.2 [Rev ] Pipe Embedment for 16-inch and smaller water mains
1.11.3 [Rev ] Installation of Bentomat© CL Geosynthetic Clay Liner on Water Pipe and Fittings
1.12.1 [Rev ] Installation of Polyethylene Encasement on Cast or Ductile Iron Pipe and Fittings
1.13.1 [Rev ] Water Mains Crossing Sanitary Sewers
1.14.1 [Rev ] Installation of Trace Wire on Water Mains
2.0.1 [Rev ] Direction of Water Valve Operation
2.2.0 [Rev ] Gate Valve Installation on 16-inch and smaller PVC water mains
2.3.0 [Rev 09-26-24] Division Check Valve and Division Valve Installation on Water Mains
3.0.1 [Rev ] Hydrant Installation on 6-inch, 8-inch, 12-inch and 16-inch Mains
3.0.2 [Rev ] Fire Hydrant Spacing
3.1.1 [Rev ] Obsolete Fire Hydrants
3.1.2 [Rev ] Hydrant Color and Nozzle Thread Design
5.5.3 [Rev ] Use and Installation of Retainer Glands
6.0.5 [Rev 02-12-24] 3/4-inch, 1-inch, 1-1/2-inch, or 2-inch Service Taps on C900 PVC Water Mains
8.2.1 [Rev ] Installation of a Single Insulating Washer Flange Insulating Set
8.2.2 [Rev ] Installation of a Double Insulating Washer Flange Insulating Set
8.5.2 [Rev ] Application of Tapes and Wraps for Water Pipelines
11.7.0 [Rev ] Installation of Electrofusion Couplings, Saddles & Flex Restraints on HDPE Water Mains
11.7.1 [Rev ] Sidewall Fusion of Tess and Saddles on HDPE Water Mains
File No. 416128 (MUD 119) [Rev ] CC Valve Box for Water or Gas Gate Valves
File No. 416206 (MUD 119) [Rev ] 24-inch Manhole Ring and Cover
File No. 416207 (MUD 119) [Rev ] 24-inch Manhole Ring and Cover
File No. 416232 (MUD 119) [Rev ] 36-inch Manhole Ring and Cover
MUD 125(MUD119) FIG 1 [Rev ] 6-inch Chlorine Tube for Contractors
MUD 125(MUD119) FIG 2 [Rev ] 8-inch Chlorine Tube for Contractors